ETCO2 Monitor and Sensors
ETCO2 Monitor
Brand | Ananta Medisystems |
Parameters | EtCO2 |
Battery Backup | 1-Hour Continuous Working |
Model Name/Number | AM-ETCO2MTR |
Battery | Rechargeable Lithium Battery (About 6 Hours) |
Communication | Wi-Fi, BLE, Zigbee |
- 7” TFT-LCD Display, Support Capacitive Touch screen
- Support Various Modules Including 3/5 Leads ECG
- Support Multi-Display Interface; LCD, HDMI, Miracast
- Support Multi-Communication Interface; Wi-Fi, BLE, Zigbee
- Built-in Detachable Rechargeable Lithium Battery (About 6 Hours)
- Support Multi-Language, Central Monitoring system
- The AM-ETCO2MTR Monitor Supports the Display of Two Waveforms and up to Eight Parameters
- Standard with Side-stream EtCO2, Easily Changeable to Mainstream by Advanced Order
- Solid State Side-stream Module, Single Beam, Non-Dispersive Infrared (NDIR) Absorption, Ratio-metric Measurement
- Initialization Time: Capnogram within 10Sec., Full Specification within 60 sec., Routine Calibration is not Required, 8 Sec Zero Performed when Power ON or Ambient Temperature Changing Too Faster
- Sampling Flow Rate: 100 mL/min (Can be set from 50 to 200mL/min) with SPO2 & Respiration
- Infrared Absorption
- Parameters: ECG, NIBP, SPO2, Temp, Pulse Rate, Respiration
ETCO2 Main Stream
Usage/Application | Hospital |
Transducer Type | Mainstream |
Model Name/Number | AM-ETCO2MS |
Brand | Ananta Medisystems |
Measurment Range | 0-150 mmHg |
Type | Mainstream CO2 Sensor |
Type Of Equipment | Sensor |
ETCO2 Accuracy | CO2 40mm Up to 2 mmHg |
Operating Temperature | 45 Degree Celsius |
Certification | CE, RoHS Compliant |
Compatible For | Philips , Mindray , Nellcor , Masimo , GE , Comen |
- AM-ETCO2MS is a Highly Integrated Main-Stream CO2 Sensor
- One Step Capnography Solution for Patient Monitoring System
- Within a Very Compact Size, It Provides Measurement of End-Tidal Carbon Dioxide (EtCO2), Respiration Rate, Capnogram, Which Can Cover Most of Requirement from the Patient Monitoring System
- With a Very Simple RS232 Interface and Industry Compatible Protocol, It's Fairly Easy to Connect AM-ETCO2MS to Any Patient Monitoring System or Other Medical Treatment System Where CO2 Sensor is Needed
- With the Stability, Flexibility and Easy to Use Built-in Essence, AM-ETCO2MS is Ideal Choice for Capnography Subsystem
- Real Time CO2 Monitoring and Data Upload
- Dual Wavelength, Non-Dispersive Infrared (NDIR) with Single Beam Optics, Fast Electrical Modulation MEMS IR Source and Non-Moving Part for Enduring Usage
- Includes Temperature Control System, To Prevent Airway Adapter Condensing, Barometer Pressure and Gas Temperature Compensation
- No Routine User Calibration Required, Small Size, Lightweight and Stability Easy to Use Flexibility
Reusable Ibp Extension Cable
Usage/Application | Hospital |
Model Name/Number | Reusable IBP Extension Cable |
Brand | Ananta Medisystems |
Type | IBP Extension Cable |
Material | Rubber |
Type Of Equipment | Cable |
Feature | Reusable |
- Its Reusable Simple & Compact
- Round Socket Pin
- Its Very Durable and Long Lasting
Contec IBP Module
Brand | Contec |
Part Number | IBP Module |
Sensor Type | IBP |
Data Processing | Automatic |
Used For | Adult, Infant |
Type | Sensor |
- The product is a high accuracy blood pressure measure equipment which is used with corresponding monitor. It can measure the blood pressure monitor of adult,enfant and infant
- Plug and play IBP technique
- It is fit for adult,enfant and infant
- Low-power consumption, dispense with special power supply
- Automatic digital data processing
Etco2 Mainstream Module
Transducer Type | Mainstream |
Brand | CONTEC |
Model Number | CO2-MO2 |
Measurment Range | 0-150 mmHg |
Certification | FDA |
Compatible For | CMS7000, CMS8000, CMS9000 |
· Mainstream EtCO2 Module is a non-dispersive infrared analyzer. In Module, infrared light is generated by the Module and beamed through the sample cell to a detector on the opposite side. CO2 from the patient that is aspirated into the sample cell absorbs some of this infrared energy. The Module determines CO2 concentration in the breathing gases by measuring the amount of light absorbed by these gases. The Module contains a reference channel, used to compensate for optical changes, so that the system is in a state of calibration. EtCO2 is displayed as a numerical value in millimeters of mercury (mmHg), percent (%), or kilopascals (kPa). In addition, a CO2 waveform (capnograph) may be displayed which is a valuable clinical tool that can be used to assess patient airway integrity and proper endotracheal tube (ETT) placement.
· Respiration rate is calculated by measuring the time interval between detected breaths.
Portable and Modular design- Elegant in appearance, clear in labeling and easy to operate.
- Modular design, small and lightweight. Work with monitor to continuously measure CO2 concentration in gas and calculate End-tidal CO2 (ETCO2), Inspired Minimum CO2 (InsCO2) and Airway Respiration Rate (AwRR)
Optional measurement units
· Multiple measurement units to choose: mmHg, kPa and %.
ETCO2 Side Stream With Water Tap
Brand | Ananta Medisystems |
Usage/Application | Hospital |
Model Name/Number | AM-ETCO2-SSW |
Prescription/Non prescription | Non prescription |
Type | Multi-gas Analyser |
Type Of Equipment | Sensor |
Accuracy | Up to 1 Breath |
Sample Rate | 103 mL/min |
Calibration | No Routine User Calibration Required |
Power Consumption | Less than 2.0 Watts Typical |
Interface | RS-232 Operating at 9600 bps |
Respiration Rate | Range 150 Breaths/ Min |
- The AM-ETCO2-SSW Series Multi-gas Analyser is the Ideal Low Sampling-Rate Anaesthesia Solution for Your Patient Monitoring System
- AM-ETCO2-SSW Show an Accurate Gas Concentration with All Respiration Rates Up To 150 Breaths Per Minute
- Advanced Technology Enables AM-ETCO2-SSW To Provide Accurate Measurement of CO2, N2O, Anesthetic
- Agents Gas, Respiration Rate, Inspiration Time and Expiration Time with a Sampling-Rate Low to 50 mL/min
- AM-ETCO2-SSW is Ideal for Use on Adult, Pediatric and Infant Patients, Patients Undergoing Procedural Sedation and Shot-Term Monitoring of Intubated Patients
- State of the Art Non-Dispersive Infrared (NDIR) Technology
- CO2, N2O and Anaesthesia Multi-gas Monitoring
- Real-time and Continuous Measurement of Gas Concentrations and Respiratory Rate
- Sample Rate low to 100 mL/min
- Barometer Pressure and Temperature Compensation
- Fast Warmup Time Ensures Full Accuracy Within 2 Minutes
- Low Power Consumption Less Than 2W